QImaging MicroPublisher 3.3 MicroPublisher 5.0 both color
|
Bayer color (RGB primary color mosaic filters on chip). Bayer color sensor reads 2 fields/frame, reading out odd then even pixels. 30-bit color, available cooled and non-cool
|
2 fields w same exposure times but not simultaneously. Time difference between 2 field readouts 105ms 8-bit, 210ms 10-bit. Sensor designed for still images.
|
Publication of high res still color images in brightfield and fluorescence clinical, life science and animation w video-like, full field of view frame rates up to 30fps.
|
yes and yes Click here for more infon on cameras for deconvolution
|
|
|
QImaging Intensified Retiga
|
monochrome camera. RGB color filter (F-mount interface); GaAs photocathode Extended Blue option, 350-900nm; Standard Gen III 475-900nm
|
Requires 18mm Gen III image intensifier w high-speed intensifier gate control for nanosecond exposures, blue
|
Offers high sensitivity for low-light, fluorescent imaging and detection of single photon events. Good for high-speed imaging, stop action imaging
|
low excitation, chemiluminescence bioluminescence, single molecule fluorescence, flow
|
|
|
QImaging Retiga 2000R Series (New) mono or color
|
Color Bayer Mosaic, 12 bit. Camera available in mono and color, cooled and non-cooled; RGB color filter for mono cameras (F-mount interface)
|
$2,500 for RGB liquid crystal color filter module. Optional IR cutoff filter available. Requires export license (ITAR).
|
brightfield, phase-contrast, darkfield; live cell; pathology, histology, cytology, FISH, calcium, DNA, metallurigical, semiconductor, forensic
|
yes, fluorescence imaging in life science and industrial applications
|
|
|
QImaging Retiga EXi Series mono or color
|
Bayer Mosaic non-cool, or cool color. RGB color filter for mono cameras (F-mount), IR filter available for mono
|
13 watt requirement for cooled, color, external power supply may be required in addition to standard Firewire
|
enhanced visible and IR QE, including green fluorescent protein (GFP), see apps listed above for 2000R.
|
quantitative, ultra low light, NIR bright, darkfield, industrial
|
|
|
QImaging Retiga 1300i
|
Available in color cooled and color non-cooled models. 1300i is compatible w Retiga 1300R line.
|
Bayer Mosaic CCD is high speed, low cost, C-mount. 4096 gray levels.
|
calcium, fluorescence, pathology, cytology, forensics, biology, metallurgy, genetics, geology, pharmaceutical, quality, low light, brightfield, high speed, industrial
|
yes/yes Click here for info on cameras for deconvolution
|
9.5
|
|
QImaging QICAM and QICAM-IR mono or color infrared mono
|
Bayer Mosaic for QICAM, available in mono "Fast" and Color "Fast, both cooled, plus mono "Fast" not cooled. "IR" version mono only.
|
limited to 12 bit, QICAM-IR has no color filter option
|
high-res, infrared and visible-range scientific and industrial imagined, spectral range extends to 1000nm in IR gegion. Frame rates up to 120 fps w bin and ROI.
|
QICAM-IR best for real-time, low-light infrared imaging
|
|
|
QImaging PMI-4201class1 PMI-4202 class2 PMI-4201 class3
|
removable RGB color filter available for all mono cameras Class 1, 2, or 3 CCD. $12,000 deposit required for Class 1, $6,000 Class 2, $5,000 Class 3, non-refundable.
|
4096 gray levels, optional $2,500 for RGB liquid crystal color filter module. Optional IR cutoff filter available.
|
Industrial inspection, automated, high resolution for quantitative imaging , 4.2 million pixels. Wide field of view for inspection.
|
Specialty Apps, linear, stable digital data at fast read-out, gamma = 1, programmable gain
|
|
|
|
Cooke PixelFly
|
?Camera available in mono or color. Optional integration with liquid crystal filter?
|
??
|
Brightfield/DIC, fluorescence, gel documentation, machine vision, spray, live cell (GFP/BFP), spectroscopy, ballistics, particle image velocimetry, FLIM, medical X-ray, lowlight, particle tracking
|
?yes/yes? Click here for more information on cameras for deconvolution
|
|
|
|
Cooke SensiCam
|
Bayer filter and algorithm that calculates RGB values of each pixel (matrix of 4x4 pixels). Digitized via 12-bit A/D, then assigned RGB value. 36-bit image file. Available in VGA or SVGA, mono or color.
|
Monitor can only show 8-bits per color, so user can only see 24-bits at a given time. User has 36-bit data and can choose which 24-bits are seen at a given time.
|
most fluorescent imaging; general imaging; QE suitable for calcium imaging, deconvolution, laser induced fluorescence, industrial inspection
|
yes/yes Click here for more information on cameras for deconvolution
|
9.0
|
|
PixelLINK PL-A641 mono PL-A642 color
|
color: RGB Bayer with microlenses
|
?
|
Microscopy; Medical and biometric imaging; Video conferencing; Surveillance and security; Photo ID
|
?
|
|
|
Optronics MagnaFire SP QuantiFire mono MicroFire mono or color MacroFire color
|
SP "Color Merge" permits user-selectable image file overlays for imaging w external cubes, filters, custom mono-, bi-, or tri-chromatic imaging; Quanti is mono; Micro is color; Macro is color or mono
|
Dichroic filters faster than acousto-optical filters. Color requires 3 images and merge process. Mechanical filter wheel introduces vibrations.
|
SP for general scienftific. Micro for fluorescent, brightfield color; Macro for fluorescent, brightfield color or mono; Quanti for quantitative specimen analysis in extreme low-light, fluorescence or NIR
|
SP ok for bright, non-bleaching specimens; SP has "Turbo Image Gain" to reduce exposure duration
|
4.5 fluor. 8.5 bright; SP not yet rated
|
|
Hamamatsu C9100-02 C9100-12
|
Monochrome camera
|
N/A
|
Intracellular ion imaging, real time observation of circulating blood cells, fast tracking of small particles, single molecule observation at photon level, high speed fluorescence cell tomography
|
yes/yes Click here for more information on cameras for deconvolution
|
|
|
Hamamatsu Orca II ERG Orca II ER Orca-AG
|
Monochrome cameras
|
N/A
|
most fluorescent imaging, GFP, DNA Ploidy analysis, Red and Near infrared, Motility, inspection, X-ray scintillator readout, calcium, deconvolution, pathology
|
yes/yes
|
|
|
Hamamatsu C7780-10
|
3 chip CCD with RGB prism. 36 bit color images in a single exposure, but w independent exposure times for each R, G, and B CCD. Cooled to 0C.
|
?
|
Color digital time-lapse, fluorescence resonance energy transfer, fluorescence In Situ Hybridization, histology, pathology, cytology
|
yes/yes
|
|
|
Diagnostics Spot RT Mono RT Color RT Color Slider Insight
|
3 shot RGB liquid crystal filter controlled/powered by camera. Insight, Bayer Mosaic w high speed color interpolation for real time color imaging.
|
Still specimens needed for 3 shot acquisition. Insight, Bayer Mask CCD offers less color resolution than 3 shot cameras
|
Brightfield, general imaging, DIC, standard fluorescence, histology, pathology. Insight, as above plus very bright fluorescence
|
yes, yes
|
|
|
DVC Co. 1412AM 1412AC 1412-MS 1412 Intensicam
|
DVC-1412AC is color, available w LVDS, CameraLink or Firewire interface. RGB color via on-sensor Bayer filter pattern. 1412-MS can be supplied w RGB optical filter sets, w custom sets, or Qdot filters.
|
?
|
Intensicam good for Single Molecule tracking, fast decaying fluorescence. All 1412 cameras good for drug discovery, fluorescence microscopy, quantum dots, chemiluminescence, cell biology, inspection
|
yes, yes
|
|
|
Dage 300 not cooled 300T cooled
|
N/A
|
N/A
|
brightfield imaging, pathology and histology, general imaging
|
see comments/ ok for bright, non-bleaching
|
4.5 fluor. 8.5 bright
|
|
Dage 330 not cooled 330T cooled
|
color 30 fps and comes from a masked chip, Bayer filter
|
very fast at 30 fps, but Bayer filter results in lower quality
|
brightfield imaging, pathology and histology, general imaging
|
see comments/ ok for bright, non-bleaching
|
4.5 fluor. 8.5 bright
|
|
Dage Series 70
|
color 30 fps and comes from a masked chip, Bayer filter
|
very fast at 30 fps, but Bayer filter results in lower quality
|
digital analysis, quantitative measuring, medical imaging requiring a small, lightweight sensing head
|
?Click here for more information on cameras for deconvolution
|
|
|
Roper Cascade 512F
|
?
|
?
|
low-light level, single-molecule fluorescence, live-cell
|
yes/yes
|
|
|
Roper Sensys
|
monochrome camera, add CRI filter to get color
|
CRI filter slower than Bayer on dichroics, but gives high quality color images
|
most fluorescent/ deconvolution; very good w red dyes; too slow for rapid acquisition
|
yes/yes
|
7.5
|
|
Roper Quantix
|
monochrome camera, add CRI filter to get color
|
CRI filter slower than Bayer on dichroics, but gives high quality color images
|
most fluorescent/ deconvolution; very good w red dyes
|
yes/yes
|
8.5
|
|
Roper CoolSNAPfx CoolSNAPcf mono or color
|
Color mask: RGB Bayer mosaic filter
|
CRI filter slower than Bayer on dichroics, but gives high quality color images
|
most fluorescent, general, calcium; cf ideal for high-res microscopy and inspection, deconvolution
|
yes/yes Click here for infon on cameras for deconvolution
|
8.0
|
|
Roper CoolSNAPHQ CoolSNAP ES mono
|
? ES is monochrome
|
?
|
ES is for low-light scientific and industrial applications, near infrared, live-cell imaging
|
?
|
|
|
Roper Princeton Micromax 1300Y and 1300Y HS
|
monochrome camera, add CRI filter to get color
|
CRI filter slower than Bayer on dichroics, but gives high quality color images
|
most fluorescent imaging; general imaging, deconvolution
|
yes/yes
|
7.5
|
|
Nikon Coolpix 995
|
256 element matrix metering and white balance for exposure quality and color balance
|
?? ISO 100 equivalent; 200, 400, 800, Auto; can be controlled in any exposure mode
|
?
|
??Click here for infon on cameras for deconvolution
|
|
|
Nikon DXM 1200
|
?
|
?
|
Photomicrogaphic
|
?
|
|
|
Zeiss AxioCam MR med res HR high res
|
MR ccd w or w/o RGB color mask, MRc Bayer color filter mask, or BG 40 IR blocking filter; HR patented "Co Site Sampling" RGB, 36 bit color
|
N/A for MRmono Proprietary Co Site Sampling requires use of AxioVision software
|
MR biology, medicine, materials analysis. HR all microscopy and macroscopy applications, biomedicine, materials analysis, quality-assurance, fluorescence imaging.
|
??Click here for infon on cameras for deconvolution
|
|
|
|
Sony DXC-S500
|
RGB primary color filter
|
?
|
?
|
?
|
|
|