Camera
|
Color Acquisition Method |
Color Tradeoffs |
Appropriate Applications |
Deconvolution?
Fluorescence Microscopy? |
VayTek
Rating
10 is best |
|
QImaging
MicroPublisher 3.3
MicroPublisher 5.0
both color
|
Bayer color (RGB primary color mosaic filters on chip). Bayer color sensor reads 2 fields/frame, reading out odd then even pixels. 30-bit color, available cooled and non-cool |
2 fields w same exposure times but not simultaneously. Time difference between 2 field readouts 105ms 8-bit, 210ms 10-bit. Sensor designed for still images. |
Publication of high res still color images in brightfield and fluorescence clinical, life science and animation w video-like, full field of view frame rates up to 30fps. |
yes and yes
Click here for more infon on cameras for deconvolution |
none
yet |
|
QImaging
Intensified Retiga
|
monochrome camera. RGB color filter (F-mount interface); GaAs photocathode Extended Blue option, 350-900nm; Standard Gen III 475-900nm |
Requires 18mm Gen III image intensifier w high-speed intensifier gate control for nanosecond exposures, blue |
Offers high sensitivity for low-light, fluorescent imaging and detection of single photon events. Good for high-speed imaging, stop action imaging |
low excitation, chemiluminescence bioluminescence, single molecule fluorescence, flow |
none yet |
|
QImaging
Retiga 2000R Series (New)
|
Color Bayer Mosaic, 12 bit. Camera available in mono and color, cooled and non-cooled; RGB color filter for mono cameras (F-mount interface) |
$2,500 for RGB liquid crystal color filter module. Optional IR cutoff filter available. Requires export license (ITAR). |
brightfield, phase-contrast, darkfield; live cell; pathology, histology, cytology, FISH, calcium, DNA, metallurigical, semiconductor, forensic |
yes, fluorescence imaging in life science and industrial applications |
none yet |
|
QImaging
Retiga EXi Series
color or mono
"Fast" or standard
|
Bayer Mosaic non-cool, or cool color. RGB color filter for mono cameras (F-mount), IR filter available for mono |
13 watt requirement for cooled, color, external power supply may be required in addition to standard Firewire |
enhanced visible and IR QE, including green fluorescent protein (GFP), see apps listed above for 2000R. |
quantitative, ultra low light, NIR bright, darkfield, industrial |
none yet |
|
QImaging
Retiga 1300i
|
Available in color cooled and color non-cooled models. 1300i is compatible w Retiga 1300R line. |
Bayer Mosaic CCD is high speed, low cost, C-mount. 4096 gray levels. |
calcium, fluorescence, pathology, cytology, forensics, biology, metallurgy, genetics, geology, pharmaceutical, quality, low light, brightfield, high speed, industrial |
yes/yes
Click here for info on cameras for deconvolution |
9.5 |
|
QImaging
QICAM and
QICAM-IR
infrared mono
|
Bayer Mosaic for QICAM, available in mono "Fast" and Color "Fast, both cooled, plus mono "Fast" not cooled. "IR" version mono only. |
limited to 12 bit, QICAM-IR has no color filter option |
high-res, infrared and visible-range scientific and industrial imagined, spectral range extends to 1000nm in IR gegion. Frame rates up to 120 fps w bin and ROI. |
QICAM-IR best for real-time, low-light infrared imaging |
none yet |
|
QImaging
PMI-4201class1
PMI-4202 class2
PMI-4201 class3
|
removable RGB color filter available for all mono cameras Class 1, 2, or 3 CCD. $12,000 deposit required for Class 1, $6,000 Class 2, $5,000 Class 3, non-refundable. |
4096 gray levels, optional
$2,500 for RGB liquid crystal color
filter module. Optional IR cutoff filter available. |
Industrial inspection, automated, high resolution for quantitative imaging , 4.2 million pixels. Wide field of view for inspection. |
Specialty Apps, linear, stable digital data at fast read-out, gamma = 1, programmable gain |
none
yet |
|
Camera
|
Color Acquisition Method |
Color Tradeoffs |
Appropriate Applications |
Deconvolution?
Fluorescence Microscopy? |
VayTek
Rating
10 is best |
|
Cooke PixelFly
|
?Camera available
in mono or color. Optional integration with liquid crystal filter? |
?? |
Brightfield/DIC, fluorescence, gel documentation, machine vision, spray, live cell (GFP/BFP), spectroscopy, ballistics, particle image velocimetry, FLIM, medical X-ray, lowlight, particle tracking |
?yes/yes?
Click here for
more information on cameras for deconvolution |
none
yet |
|
Cooke SensiCam
|
Bayer filter and algorithm that calculates RGB values of each pixel (matrix of 4x4 pixels). Digitized via 12-bit A/D, then assigned RGB value. 36-bit image file. Available in VGA or SVGA, mono or color. |
Monitor can
only show 8-bits per color, so user can only see 24-bits at a
given time. User has 36-bit data and can choose which 24-bits
are seen at a given time. |
most fluorescent
imaging; general imaging; QE suitable for calcium imaging, deconvolution,
laser induced fluorescence, industrial inspection |
yes/yes
Click here for
more information on cameras for deconvolution |
9.0 |
|
PixelLINK
PL-A641 mono
PL-A642 color
|
color: RGB
Bayer with microlenses |
? |
Microscopy;
Medical and biometric imaging; Video conferencing; Surveillance
and security; Photo ID |
? |
none
yet |
|
Optronics
MagnaFire SP
QuantiFire mono
MicroFire mono or color
MacroFire color
|
SP "Color Merge" permits user-selectable image file overlays for imaging w external cubes, filters, custom mono-, bi-, or tri-chromatic imaging; Quanti is mono; Micro is color; Macro is color or mono |
Dichroic filters faster than acousto-optical filters. Color requires 3 images and merge process. Mechanical filter wheel introduces vibrations. |
SP for general scienftific. Micro for fluorescent, brightfield color; Macro for fluorescent, brightfield color or mono; Quanti for quantitative specimen analysis in extreme low-light, fluorescence or NIR |
see Next Page
SP ok for bright, non-bleaching specimens; SP has "Turbo Image Gain" to reduce exposure duration |
4.5
fluor. 8.5 bright; SP not yet rated |
|
Hamamatsu
C9100-02
C9100-12
|
Monochrome camera |
N/A |
Intracellular ion imaging, real time observation of circulating blood cells, fast tracking of small particles, single molecule observation at photon level, high speed fluorescence cell tomography |
yes/yes
Click here for
more information on cameras for deconvolution |
none yet |
|
Hamamatsu
Orca II ERG
Orca II ER
Orca-AG
|
Monochrome cameras |
N/A |
most fluorescent imaging, GFP, DNA Ploidy analysis, Red and Near infrared, Motility, inspection, X-ray scintillator readout, calcium, deconvolution, pathology |
yes/yes |
none yet |
|
Hamamatsu
C7780-10
|
3 chip CCD with RGB prism. 36 bit color images in a single exposure, but w independent exposure times for each R, G, and B CCD. Cooled to 0C. |
? |
Color digital time-lapse, fluorescence resonance energy transfer, fluorescence In Situ Hybridization, histology, pathology, cytology |
yes/yes |
none yet |
|
Camera
|
Color Acquisition Method |
Color Tradeoffs |
Appropriate Applications |
Deconvolution?
Fluorescence Microscopy? |
VayTek
Rating
10 is best |
|
Diagnostics Spot RT Mono
RT Color
RT Color Slider
Insight
|
3 shot RGB liquid crystal filter controlled/powered by camera. Insight, Bayer Mosaic w high speed color interpolation for real time color imaging. |
Still specimens needed for 3 shot acquisition. Insight, Bayer Mask CCD offers less color resolution than 3 shot cameras |
Brightfield, general imaging, DIC, standard fluorescence, histology, pathology. Insight, as above plus very bright fluorescence |
yes, yes |
none
yet |
|
DVC Co.
1412AM
1412AC
1412-MS
1412 Intensicam
|
DVC-1412AC is color, available w LVDS, CameraLink or Firewire interface. RGB color via on-sensor Bayer filter pattern. 1412-MS can be supplied w RGB optical filter sets, w custom sets, or Qdot filters. |
? |
Intensicam good for Single Molecule tracking, fast decaying fluorescence. All 1412 cameras good for drug discovery, fluorescence microscopy, quantum dots, chemiluminescence, cell biology, inspection |
yes, yes |
none yet |
|
Dage
300 not cooled
300T cooled
|
N/A |
N/A |
brightfield
imaging, pathology and histology, general imaging |
see comments/
ok for bright, non-bleaching |
4.5
fluor. 8.5 bright |
|
Dage
330 not cooled
330T cooled
|
color 30 fps and comes from a masked chip, Bayer filter |
very fast at 30 fps, but Bayer filter results in lower quality |
brightfield
imaging, pathology and histology, general imaging |
see comments/
ok for bright, non-bleaching |
4.5
fluor. 8.5 bright |
|
Dage
Series 70
|
color 30 fps and comes from a masked chip, Bayer filter |
very fast at 30 fps, but Bayer filter results in lower quality |
digital analysis, quantitative measuring, medical imaging requiring a small, lightweight sensing head |
?Click here for
more information on cameras for deconvolution |
none
yet |
|
Camera
|
Color Acquisition Method |
Color Tradeoffs |
Appropriate Applications |
Deconvolution?
Fluorescence Microscopy? |
VayTek
Rating
10 is best |
|
Roper
Cascade 512F
|
? |
? |
low-light level, single-molecule fluorescence, live-cell |
yes/yes |
none
yet |
|
Roper
Sensys
|
monochrome
camera, add CRI filter to get color |
CRI
filter slower than Bayer on dichroics, but gives high quality
color images |
most fluorescent/ deconvolution; very good w red dyes; too slow for rapid acquisition |
yes/yes |
7.5 |
|
Roper
Quantix
|
monochrome
camera, add CRI filter to get color |
CRI
filter slower than Bayer on dichroics, but gives high quality
color images |
most fluorescent/ deconvolution; very good w red dyes |
yes/yes |
8.5 |
|
Roper
CoolSNAPfx CoolSNAPcf
mono or color
|
Color
mask: RGB Bayer mosaic filter |
CRI
filter slower than Bayer on dichroics, but gives high quality
color images |
most fluorescent, general, calcium; cf ideal for high-res microscopy and inspection, deconvolution |
yes/yes
Click here for infon on cameras for deconvolution |
8.0 |
|
Roper
CoolSNAPHQ
CoolSNAP ES mono
|
?
ES is monochrome |
? |
ES is for low-light
scientific and industrial applications, near infrared, live-cell
imaging |
? |
none
yet |
|
Roper Princeton
Micromax 1300Y
and 1300Y HS
|
monochrome
camera, add CRI filter to get color |
CRI
filter slower than Bayer on dichroics, but gives high quality
color images |
most fluorescent
imaging; general imaging, deconvolution |
yes/yes |
7.5 |
|
Camera
|
Color Acquisition Method |
Color Tradeoffs |
Appropriate Applications |
Deconvolution?
Fluorescence Microscopy? |
VayTek
Rating
10 is best |
|
Nikon
Coolpix 995
|
256 element matrix metering and white balance for exposure quality and color balance |
?? ISO 100 equivalent; 200, 400, 800, Auto; can be controlled in any exposure mode |
? |
??Click here for infon on cameras for deconvolution |
? |
|
Nikon
DXM 1200
|
? |
? |
Photomicrogaphic |
? |
? |
|
Zeiss AxioCam
MR med res
HR high res
|
MR ccd w or w/o RGB color mask, MRc Bayer color filter mask, or BG 40 IR blocking filter; HR patented "Co Site Sampling" RGB, 36 bit color |
N/A for MRmono
Proprietary Co Site Sampling requires use of AxioVision software |
MR biology, medicine, materials analysis.
HR all microscopy and macroscopy applications, biomedicine, materials analysis, quality-assurance, fluorescence imaging. |
??Click here for infon on cameras for deconvolution |
none yet |
|
Sony DXC-S500
|
RGB primary color filter |
? |
? |
? |
? |